Mecer 1200VA 720W 12V Inverter (Not compatible with Lithium Ion)
IVR-1200LBK
rated at Takealot ยท checked Yesterday
- Average
- R 2 206.34
- Lowest seen
- R 1 599.00
- Highest seen
- R 4 295.00
- Last change
- R 92.00
- First indexed
- 03 May 2017
- Vendor
- Takealot
Mecer 1200VA 720W 12V Inverter - Setup Instructions
COMPLUSORY SPECIAL INSTRUCTIONS TO FOLLOW
This inverter must be installed by a qualified electrician. Incorrect installation can result in electrical shock, damage to equipment, or fire. The inverter will not power on until all required connections are properly made.
What's Included
Mecer 1200VA / 720W Inverter Unit (12V DC)
User Manual
AC Input Power Cable
AC Output Sockets (on the unit)
Cooling Fan (built-in)
What You'll Need
12V Deep Cycle Battery (minimum 100Ah recommended)
12V Battery Cables (with correct gauge and terminals)
Circuit breaker or fuse (recommended for DC side protection)
Tools for electrical connections (used by the electrician)
Installation Steps (By a Qualified Electrician Only)
1. Choose a Safe Location
Install indoors in a well-ventilated, dry, and cool space.
Keep away from flammable materials and direct sunlight.
2. Connect the Battery
Ensure the inverter ON/OFF switch is OFF.
Connect the positive (+) terminal of the battery to the positive (+) DC input of the inverter.
Connect the negative (-) terminal of the battery to the negative (-) DC input.
Use correct polarity to avoid damage.
Note: A fuse or circuit breaker should be installed between the battery and inverter on the positive cable for safety.
3. Connect the AC Input (Optional)
If you plan to use grid power to charge the battery via the inverter's built-in charger, connect the AC input to a suitable wall outlet or DB board via an isolator or dedicated breaker.
4. Connect the AC Output
Connect essential appliances (TV, router, lights, etc.) to the AC output sockets or wire into an essential loads DB board.
Do not exceed the 720W limit.
5. Check Connections
Double-check all connections: battery polarity, tightness of terminals, and grounding if required.
6. Power On
Once all connections are complete and safe:
Turn on the battery breaker (if used).
Flip the inverter's power switch to ON.
The inverter should now power on and begin supplying power or charging.
Notes
The inverter will not turn on if the battery is not connected or is improperly connected.
Never operate the inverter without a battery connected.
This inverter is not designed to power high-load appliances like kettles, stoves, or heaters.
Operation Tips
Regularly check battery water levels (if using lead-acid).
Keep ventilation ports clear of dust.
Do not overload the inverter.
Maintenance & Support
If the unit emits continuous beeping or shows an error light, refer to the user manual or contact a professional or Mustek Limited PTY LTD as the warranty is held with Mustek South Africa.
Do not open the unit yourself-risk of electric shock.
xxPlease note that batteries are not included and needs to be bought separatelyxx
This unit is also intended for use with IT equipment and will not be able to run a kettle, heater or anything that uses a motor or an element.
Features:
- Simulated sine wave inverter
- Built-in AVR for voltage regulation
- Wide input voltage range: 90-280 VAC
- 12VDC available
- Overload and short circuit protection
- LCD display for comprehensive information
Specifications:
- MODEL Mecer IVR-1200LBK
- CAPACITY 1200 VA / 720 W
- POWER FACTOR 0.8
- Input Voltage range 90-280VAC
Line Mode:
- Output Voltage
- Bypass mode: 0utput voltage same as input voltage
- AVR mode: Output voltage = Input voltage 1.2 at Input voltage - Output Frequency Same as input
Battery Mode (BATTERIES NOT INCLUDED):
- Output Voltage 230Vac +/-10%
- Transfer Time 20ms typical
- Waveform Modified Sine-wave
Overload Capability:
- Bypass Mode (in VA and Watts) Load >110%+/-15% , alarm 5 mins then fault
- Load >130% +/-15%, fault immediately.
- AVR Mode (in VA and Watts)at Input voltage > 170VAC Load >100%+/-15%, go to bypass mode
- AVR Mode (in VA and Watts)at Input voltage < 170VAC Load >60%+/-15%, go to bypass mode
- Battery Mode (in W) Load>110% +/-15%, overload alarm for 15s, and then will switch to fault mode for 10s. Then unit will re-start for 5 times Load>120% +/-15% , fault & cut off O/P immediately.
Short Circuit Protection:
- Line Mode Breaker
- Battery Mode Current limit +Firmware Protection
Battery specs needed (NOT INCLUDED):
- Battery Voltage 12VDC
- Acceptable Battery Type Rechargeable lead-acid battery, Deep discharge battery- This product is not capatible to Lithium-Ion
- Polarity Reserve Protection Yes
- Charger available I/P range 90 280V
Charger:
- Constant Current Charger Voltage 14.3VDC +/-2%
- Floating Charge Voltage 13.7VDC +/-2%
- Maximum Charge Current 10A or 20A
- DC Start Voltage >11VDC
Physical:
- Dimension, D X W X H (mm) 350 x 90 x 300
- Net Weight (kgs) 4.5
Environment:
- Operating Humidity 0 to 90% Relative Humidity(Non-condensing)
- Operating Temperature 0 degrees C to 40 degrees C
- Storage Temperature -15 degrees C to 50 degrees C
What's in the box
1x Mecer 1200VA 720W 12V Inverter