Mecer Galleon II 3-phase 10Kva 10Kw Online Tower UPS ME-10K-GA33

Mecer Galleon II 3-phase 10Kva 10Kw Online Tower UPS ME-10K-GA33

R 36 499.00

FirstShop · checked Today

View at FirstShop

2 offers · 2 retailers

Listed under the same model number

No barcode ties these listings together, so no saving is claimed. See the listings

Matched by model number; no shared barcode

Average
R 36 499.00
Lowest seen
R 36 499.00
Highest seen
R 36 499.00
Last change
R 0.00
First indexed
15 Sep 2026
Retailer
FirstShop

Each price is from PriceFind's last check of that retailer. Follow the link for the live price.

Description

Mecer Galleon II 3-phase 10Kva 10Kw Online Tower UPS ME-10K-GA33 Features True double-conversion DSP technology guarantees high performance Output power factor 1 Active power factor correction in all phases 50Hz/60Hz frequency converter mode ECO mode operation for energy saving (ECO) Emergency power off function (EPO) Generator compatible SNMP+USB+RS-232 multiple communications 3-stage extendable charging design for optimized battery performance Adjustable battery numbers for long-run model Maintenance bypass available Parallel operation with commom battery Power walk-in function *Optional parallel operation *Optional isolation transformer offers full isolation and complete common mode noise rejection Technical Specifications Specification Details Product Mecer Galleon II 3-Phase UPS Phase 3-Phase Input / 3-Phase Output Capacity 10kVA / 10kW Parallel Capability Up to 4 Units Input Nominal Voltage 3 x 400V AC (3Ph+N) / 230V AC (1Ph=N) Input Voltage Range 110-300V AC @ 50% Load 176-276V AC @ 100% Load Input Frequency Range 46-54Hz or 56-64Hz Input Power Factor 0.99 @ 100% Load Input Harmonic Distortion (THDi) <4% at Full Linear Load Output Voltage 3 x 380/400/415V AC (3Ph+N) 208/220/230/240V AC (1Ph+N) AC Voltage Regulation (Battery Mode) ±1% Output Frequency Range (Synchronized) 46-54Hz or 56-64Hz Output Frequency Range (Battery Mode) 50/60Hz ±1% or 60Hz ±0.1Hz Current Crest Ratio 3:1 (Maximum) Output Harmonic Distortion (THDv) ≤2% THD (Linear Load) ≤5% THD (Non-Linear Load) Transfer Time AC Mode to Battery Mode: Zero Inverter to Bypass: Zero Waveform (Battery Mode) Pure Sine Wave Overload Capability (AC Mode) 100%-110% for 60 Minutes 110%-125% for 10 Minutes 125%-150% for 1 Minute >150% Immediate Overload Capability (Battery Mode) 100%-110% for 60 Minutes 110%-125% for 10 Minutes 125%-150% for 1 Minute >150% Immediate Bypass Nominal Voltage 3 x 380/400/415V AC (3Ph+N) Bypass Voltage Range -30% to +20% (Adjustable) Bypass Frequency Range 46-54Hz or 56-64Hz Bypass Overload Capability >130% for 1 Minute (Default) Continuous Operation Until Breaker Protection (Optional) Battery Type 12V / 9Ah Battery Quantity 20 Batteries (10 + 10) Typical Recharge Time 4 Hours to Recover 90% Capacity Charging Current (Max.) 2A (Adjustable) Charging Voltage ±13.65V x N (N = 10) LCD Panel UPS Status, Load Level, Battery Level, Input/Output Voltage, Discharge Timer and Fault Conditions Management Smart RS-232 / USB Supported Operating Systems Windows®, Linux and Mac Optional SNMP Power Management from SNMP Manager and Web Browser Dimensions (D x W x H) 630 x 250 x 826 mm Weight 103 kg Warranty UPS: 2-year Carry-in Batteries: 6-months Carry-in *When output voltage is set as 3 x 360VAC, the output power of the unit will be de-rated to 90%. **If the UPS is installed or used in a place where the altitude is higher than maximum height, the output power will be derated 1% per 100m.